Merge tag 'video-for-2019.07-rc3' of git://git.denx.de/u-boot-video

- update for using splashfile instead of location->name
  when loading the splash image from a FIT
- updates for loading internal and external splash data from FIT
- DM_GPIO/DM_VIDEO migration for mx53 cx9020 board
- fix boot issue on mx6sabresd board after DM_VIDEO migration
- increase the max preallocated framebuffer BPP to 32 in ipuv3
  driver to prepare for configurations with higher color depth
- allow to use vidconsole_put_string() in board code for text
  output on LCD displays
This commit is contained in:
Tom Rini
2019-05-21 07:12:46 -04:00
15 changed files with 271 additions and 149 deletions

View File

@@ -303,8 +303,12 @@ static int splash_load_fit(struct splash_location *location, u32 bmp_load_addr)
{
int res;
int node_offset;
int splash_offset;
int splash_size;
const char *splash_file;
const void *internal_splash_data;
size_t internal_splash_size;
int external_splash_addr;
int external_splash_size;
bool is_splash_external = false;
struct image_header *img_header;
const u32 *fit_header;
u32 fit_size;
@@ -335,36 +339,51 @@ static int splash_load_fit(struct splash_location *location, u32 bmp_load_addr)
return -EINVAL;
}
node_offset = fit_image_get_node(fit_header, location->name);
/* Get the splash image node */
splash_file = env_get("splashfile");
if (!splash_file)
splash_file = SPLASH_SOURCE_DEFAULT_FILE_NAME;
node_offset = fit_image_get_node(fit_header, splash_file);
if (node_offset < 0) {
debug("Could not find splash image '%s' in FIT\n",
location->name);
splash_file);
return -ENOENT;
}
res = fit_image_get_data_offset(fit_header, node_offset,
&splash_offset);
if (res < 0) {
printf("Failed to load splash image (err=%d)\n", res);
return res;
/* Extract the splash data from FIT */
/* 1. Test if splash is in FIT internal data. */
if (!fit_image_get_data(fit_header, node_offset, &internal_splash_data, &internal_splash_size))
memmove((void *)bmp_load_addr, internal_splash_data, internal_splash_size);
/* 2. Test if splash is in FIT external data with fixed position. */
else if (!fit_image_get_data_position(fit_header, node_offset, &external_splash_addr))
is_splash_external = true;
/* 3. Test if splash is in FIT external data with offset. */
else if (!fit_image_get_data_offset(fit_header, node_offset, &external_splash_addr)) {
/* Align data offset to 4-byte boundary */
fit_size = ALIGN(fdt_totalsize(fit_header), 4);
/* External splash offset means the offset by end of FIT header */
external_splash_addr += location->offset + fit_size;
is_splash_external = true;
} else {
printf("Failed to get splash image from FIT\n");
return -ENODATA;
}
res = fit_image_get_data_size(fit_header, node_offset, &splash_size);
if (res < 0) {
printf("Failed to load splash image (err=%d)\n", res);
return res;
if (is_splash_external) {
res = fit_image_get_data_size(fit_header, node_offset, &external_splash_size);
if (res < 0) {
printf("Failed to get size of splash image (err=%d)\n", res);
return res;
}
/* Read in the splash data */
location->offset = external_splash_addr;
res = splash_storage_read_raw(location, bmp_load_addr, external_splash_size);
if (res < 0)
return res;
}
/* Align data offset to 4-byte boundrary */
fit_size = fdt_totalsize(fit_header);
fit_size = (fit_size + 3) & ~3;
/* Read in the splash data */
location->offset = (location->offset + fit_size + splash_offset);
res = splash_storage_read_raw(location, bmp_load_addr , splash_size);
if (res < 0)
return res;
return 0;
}
#endif /* CONFIG_FIT */