arm: mach-k3: am62: fixup thermal cooling device cpus
AM62x devices now support CPU throttling based on thermal alerts
with a Linux commit 10e7bfd8114c ("arm64: dts: ti: k3-am62: Enable
CPU freq throttling on thermal alert"). However, this functionality
does not work correctly across all variants of the AM62x SoCs
which have different numbers of Cortex-A CPU cores: AM62x1 (1 core),
AM62x2 (2 cores), and AM62x4 (4 cores). On single-core and dual-core
AM62x devices, the following error is observed in the Linux kernel:
OF: /thermal-zones/main0-thermal/cooling-maps/map0: could not find
phandle 94
OF: /thermal-zones/main1-thermal/cooling-maps/map0: could not find
phandle 94
This commit adds a fixup to dynamically adjust the cooling-device
nodes in the thermal zones based on the actual number of CPU cores
available. This resolves the issue of CPU throttling not working
correctly on single-core and dual-core AM62x devices, while
maintaining the functionality for AM62x quad-core devices.
A similar approach is implemented for example on i.MX8MM SoC.
Signed-off-by: Parth Pancholi <parth.pancholi@toradex.com>
This commit is contained in:
@@ -5,6 +5,7 @@
|
||||
|
||||
#include <asm/hardware.h>
|
||||
#include <fdt_support.h>
|
||||
#include <fdtdec.h>
|
||||
|
||||
#include "../common_fdt.h"
|
||||
|
||||
@@ -75,12 +76,47 @@ static void fdt_fixup_thermal_zone_nodes_am625(void *blob, int maxc)
|
||||
}
|
||||
}
|
||||
|
||||
static void fdt_fixup_thermal_cooling_device_cpus_am625(void *blob, int core_nr)
|
||||
{
|
||||
static const char * const thermal_path[] = {
|
||||
"/thermal-zones/main0-thermal/cooling-maps/map0",
|
||||
"/thermal-zones/main1-thermal/cooling-maps/map0"
|
||||
};
|
||||
|
||||
int node, cnt, i, ret;
|
||||
u32 cooling_dev[12];
|
||||
|
||||
for (i = 0; i < ARRAY_SIZE(thermal_path); i++) {
|
||||
int new_count = core_nr * 3; /* Each CPU has 3 entries */
|
||||
int j;
|
||||
|
||||
node = fdt_path_offset(blob, thermal_path[i]);
|
||||
if (node < 0)
|
||||
continue; /* Not found, skip it */
|
||||
|
||||
cnt = fdtdec_get_int_array_count(blob, node, "cooling-device",
|
||||
cooling_dev, ARRAY_SIZE(cooling_dev));
|
||||
if (cnt < 0)
|
||||
continue;
|
||||
|
||||
for (j = 0; j < new_count; j++)
|
||||
cooling_dev[j] = cpu_to_fdt32(cooling_dev[j]);
|
||||
|
||||
ret = fdt_setprop(blob, node, "cooling-device", cooling_dev,
|
||||
new_count * sizeof(u32));
|
||||
if (ret < 0)
|
||||
printf("Error %s, cooling-device setprop failed %d\n",
|
||||
thermal_path[i], ret);
|
||||
}
|
||||
}
|
||||
|
||||
int ft_system_setup(void *blob, struct bd_info *bd)
|
||||
{
|
||||
fdt_fixup_cores_nodes_am625(blob, k3_get_core_nr());
|
||||
fdt_fixup_gpu_nodes_am625(blob, k3_has_gpu());
|
||||
fdt_fixup_pru_node_am625(blob, k3_has_pru());
|
||||
fdt_fixup_thermal_zone_nodes_am625(blob, k3_get_max_temp());
|
||||
fdt_fixup_thermal_cooling_device_cpus_am625(blob, k3_get_core_nr());
|
||||
fdt_fixup_reserved(blob, "tfa", CONFIG_K3_ATF_LOAD_ADDR, 0x80000);
|
||||
fdt_fixup_reserved(blob, "optee", CONFIG_K3_OPTEE_LOAD_ADDR, 0x1800000);
|
||||
|
||||
|
||||
Reference in New Issue